The stereo microscope, also called "Solid microscope" or "Anatomy Mirror", can produce a positive three-dimensional space image when observing objects. The stereoscopic sense is strong, the image is clear and broad, also has the long working distance, and is the application scope very extensive common microscope. Easy to operate, intuitive, high efficiency, applicable to the electronics industry production line inspection, printed circuit board verification, printed circuit components appear in the welding defects (printing dislocation, collapse, etc.) of the verification, single Board PC verification, vacuum fluorescent display VFD verification and so on, with measurement software can measure a variety of data.

By a common primary objective lens, the two beams of the object after imaging are separated by two sets of intermediate objective lenses--the zoom lens, and then through their respective eyepiece imaging, and its magnification change is obtained by changing the distance between the intermediate Mirror Group, so it is also called "Continuous zoom microscope". With the application of the requirements of the body can be matched with a rich selection of accessories, such as fluorescence, photography, photography, cold light source and so on.

(1) After the microscope is installed, in order to ensure the supply voltage and the nominal voltage of the microscope can plug the Power plug, turn on the power switch, and select the lighting mode;

(2) According to the specimens observed, select a good table (to observe transparent specimens, the use of wool glass plate; Observe the opaque specimen, choose black and white board), load the base plate hole, and lock tightly;

(3) Loosen the fastening screws on the focusing slide, adjust the height of the mirror, visual work distance in the 80mm or so, (make it with the selected objective lens magnification of the general working distance) adjusted, locking bracket, the safety ring close to the Gioto frame and lock;

(4) Install the eyepiece, first to loosen the screws on the eyepiece tube, install the eyepiece and then tighten the screws (the eyepiece into the eyepiece tube, to be particularly careful, do not touch the lens lens surface);

(5) Adjust pupil spacing, when the user through two eyepiece observation field is not a circular field of view, should be flipped two prism box, change the eyepiece cylinder of the pupil distance, so that it can observe a fully coincident circular field (the pupil distance has been adjusted);

(6) Observation specimen (focusing on specimen). First, the visual circle on the left eyepiece tube is transferred to the 0-notch position. Normally, first from the right eyepiece tube (that is, the fixed eyepiece tube) to observe, the variable-fold cylinder (with the variable-times device model) to the highest position, rotation focusing handwheel on the specimen focus, until the image of the specimen is clear, and then turn the drum to the lowest position, at this time, with the Zootia tube observation, if not clear, along the axis to adjust the visual circle on the program Mirror tube , until the image of the specimen is clear, and then binocular observation of its focusing effect;

(7) At the end of the observation, turn off the power, remove the specimen and cover the microscope with a dust shield.

Use environment

(1) The instrument should avoid direct sunlight, high temperature, damp, dust and acid-base gas corrosion;

(2) The workshop should be kept clean, the equipment used to cover the dust cover;

(3) The microscope should be placed on a firm and stable working table;

(4) The operation should avoid dirt or finger stain lens, filter color film.

Characteristics

1. The two beams in the binocular lens are not parallel, but have a certain angle-body angle (generally 12 degrees---15 degree), so the imaging has three-dimensional sense;

2. Like an upright, easy to manipulate and dissect, this is due to the prism in the eyepiece below to turn the image upside down;

3. Although the magnification rate is not as good as the conventional microscope, it works a long distance.

4. Depth large, easy to observe the whole layer of the object being checked.

5. Large diameter of field of view.


Product Categories

Fast Track

  • Feedback
    Ningbo Yaki Optical Instrument Co.,Ltd welcomes your comments! Please fill this form to give us feedback or report any problem when experiencing our website.
  • Quick Navigation
  • Contact Us
    Address: No.118 Gaoqiao Town, Haishu District, Ningbo City, Zhejiang Province, China
    Tel: +86-574-28897736    
    Fax: +86-574-28897783    
    E-mail: yaya@yakioptic.com
Copyright © Ningbo Yaki Optical Instrument Co.,Ltd